Hirayama HV-110L Vertical Autoclave

Cambridge Scientific ID: 29707 Category: Tag: Brands:

Description

 Features & Functions

  • Electro-mechanical lid lock system: The lid can be opened and closed easily and reliably with the one-touch lever. A pressure seal method is used as a safety measure.
  • Dual interlock mechanism: The lid is locked by dually detecting the chamber pressure and chamber temperature during operation. The lock state is maintained even if an operation is manually interrupted.
  • Dual detection system for residual air: The residual air which may cause sterilization failure is dually detected to always maintain the appropriate sterilization conditions for loads. The residual air is detected at the process before pressurization (during operation of an air removal timer) and at the process of pressurization air exhaust.
  • Exhaust level can be set digitally: Fine exhaust can be performed automatically, and fine exhaust adjustment is possible even in exhaust.
  • Memory function: Set contents can be registered for each mode.
  • EU model available: EU Model: Products compliant with european Standards (ENs)

 

Specifications

  • Effective capacity: 110L
  • Chamber size (φ x H mm): 420 x 795
  • Operation mode: 4 modes (LIQUID with warming, LIQUID without warming, SOLID, DISSOLUTION), one memory for each mode
  • Temperature setting range
      • Sterilization: 105℃ – 135℃ Variable
      • Dissolution: 60℃ – 100℃ Variable
      • Warming: 45℃ – 60℃ Variable
  • Time setting range
      • Sterilization: 1 min – 250 min, Remaining time is displayed
      • Dissolution: 1 min – 60 min, Remaining time is displayed
      • Warming: 20 h, fixed
      • Auto-start: Program autoclave to start 1 min to 1 week later
  • Exhaust setting: 0% – 100%, Valve opening degree setting for LIQUID mode
  • Maximum working pressure:  0.26MPa
  • Thermometer: 5℃ – 137℃
  • Pressure gauge: 0MPa – 0.4MPa
  • Safety devices: Pressure safety valve, Over-current and earth leakage breaker, Low water cut off device
  • Alarms, error display: Low water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure, Abnormality in lid opening / closing lever lock
  • Outside dimensions (W x D x H mm): 667 x 652 x 1191
  • Weight (Approximately): 81 kg
  • Pressure vessel category: Small sized pressure vessel
  • Chamber material: Stainless steel (SUS304)
  • Power supply: AC220V / 230V / 240V, 50Hz / 60Hz   (Specify voltage when ordering.)     
  • Required power supply facility: 4.0kW
  • Power connection: Ring terminal

Contact Us